Skip to main content

Resource > Wall-Like Reinforced Concrete Columns Externally Confined by means of Glass FRP Laminates

Wall-Like Reinforced Concrete Columns Externally Confined by means of Glass FRP Laminates

November 07, 2016
concrete_column_research

Authors

Antonio De Luca, Fabio Nardone, Gian Piero Lignola, Andrea Prota, and Antonio Nanni

Publication

Advances in Structural Engineering, Vol. 16, No. 4, 2013

Abstract

This paper discusses the laboratory testing of wall-like reinforced concrete (RC) columns externally confined with glass fiber reinforced polymer (GFRP) laminates and subjected to pure axial load. Specimens were characterized by an overall length of 3.05 m (10 ft), cross-sectional dimensions of 356 by 1,041 mm (14 by 41 in). Three specimens were tested: one was unstrengthened (benchmark) and two were confined with GFRP laminates. Two different confining reinforcement ratios were considered. The experimental investigation aimed at characterizing: the confinement contribution in terms of axial strength and prevention of instability of longitudinal bars, and the sensitivity of any enhancement in performance to the confining reinforcement ratio. The experimental axial stress – axial strain curves are also discussed.

Keywords

Full-scale testing, composites, confinement, reinforced concrete, wall-like columns, rehabilitation

http://journals.sagepub.com